Description:
Features and Benefits
High performance – the right protection for any speed
The S300 Professional meets the most demanding requirements and needs of robotics and mobile applications with its extensive functionality. Up to eight protection fields can be configured. The new triple field mode allows you to activate three fields simultaneously – one protective field and two alarm fields.
In summary
Compact design
2 m or 3 m protective field range
270°scanning angle
8 sets of switchable fields
Integrated configuration memory in the system connector
EFI interface for secure communication of SICK devices
Incremental encoder inputs for speed-dependent field switching
Measurement data output via RS-422
Your benefits:
Easy integration thanks to compact design
Unbeatable cost-effectiveness – the 270° scanning angle enables complete application protection with only two scanners.
Easy installation, commissioning and maintenance for fixed and mobile applications
The variety of field sets ensures safety and productivity when protecting vehicles or moving machine parts.
Quick commissioning via configuration memory
Simple modular expansions, simple wiring and additional functions with SICK safety controllers with EFI
The correct range of protection at any speed avoids unnecessary stops.
Personnel protection and navigation support in a single device
Technical details:
PEHD (average probability of dangerous failure per hour)
8.0 x 10-8 (EN ISO 13849)
Protective field range
2m / 3m
Warning field
8 m (at 15% reflectivity)
Distance measuring range
30 m
Field set type
Triple set of fields
Number of field sets
8
Number of fields
24
Number of monitoring cases
32
Angular resolution
270°
Response Time
30 mm, 40 mm, 50 mm, 70 mm, 150 mm
Output Signal Switching Devices (OSSDs) – Output Type
PNP semiconductors, short-circuit protected, cross-circuit monitored
Supply Voltage
24 V DC (16.8 V DC …. 30 V DC)
Enclosure Classification
IP65 (EN 60529)
Operating environment temperature
-10 °C … +50 °C
Storage temperature
-25 °C … +50 °C
Vibration resistance
5g, 10Hz …. 150 Hz (IEC 61496, IEC 61496-3)
Laser class
1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
Compatibility
Configuration method: PC with CDS (Configuration and Diagnostic Software)
Configuration and diagnostic interface: RS-232
Data interface: RS-422